Construction Specialties

Защита на стени | Капаци за разширителни фуги | Входни изтривалки

0700 10 677
Меню
  • Начало
  • Продукти
    • Acrovyn® Защита за стени и врати
      Acrovyn® Врати и защита на вратите
      Acrovyn by Design® Стенни облицовки по поръчка
  • Проекти
  • Блог
  • Ресурси
    • Витрина на Acrovyn
      Брошури
      Пазарни сектори
  • За нас
  • Контакти
  • Careers

RS-5900 Rain Defence Louvres

  • RS-5900
  • 3D VIEW

RS-5900

3D VIEW

High performing louvres with vertical blades and visible mullions, offering excellent protection against wind-driven rain penetration and very good airflow.

нула
нула

INTAKE

нула

EXHAUST

нула
  • нула
    Complex extruded blade design in vertical arrangement for maximum rain defence performance
  • нула
    Channels in louvre blades to collect and drain water from the louvred area
  • нула
    Visible mullions to line up with other façade elements; invisible joint detail can be achieved if preferred
  • нула
    Delivered to site as pre-fabricated modules for efficient installation
  • нула
    Sightproof design
View 3D Model
Download Data Sheet
View Test Data

KEY FEATURES

  • Blade Orientation: Vertical
  • Mullion Type: Visible
  • Louvre Depth: 130mm
  • Blade Pitch: 38mm
  • Weight: 26kg/m2 based on a 2m x 2m module size

Download data sheet for sectional details

Download Data Sheet

PERFORMANCE

SUMMARY
  • Rain Penetration Class: A up to 3.5m/s
  • Airflow Class: 2 (entry & discharge)
  • Airflow Coefficient Ce (entry): 0.342
  • Airflow Coefficient Cd (discharge): 0.352
  • K factor (entry / discharge): 8.550 / 8.071
нула
нула

INTAKE

нула

EXHAUST

WIND DRIVEN RAIN PERFORMANCE (EN 13030:2001)
Core Ventilation Rate (m/s)0.00.51.01.52.02.53.03.5
Penetration Class (13m/s & 75mm/hr)AAAAAAAA
Effectiveness (%)10099.9199.9299.9499.9610099.99100
AirflowCoefficient of Entry Ce0.342Class 2Coefficient of Discharge Cd0.352Class 2
RESISTANCE TO AIRFLOW

RESISTANCE TO AIRFLOW – ENTRY (Ce)2

RESISTANCE TO AIRFLOW – DISCHARGE (Cd)2

Note: Based on a 1m x 1m size. Smaller louvres may have a higher Pressure Drop.

MATERIALS & FINISHES

MATERIALS
  • Aluminium alloy 6063-T6
FINISH OPTIONS
  • Mill finish
  • Clear or colour anodised
  • Polyester powder coated Matt (standard) or gloss

OPTIONAL EXTRAS

  • Head / cill / jamb cover plates
  • Blanking panels (single skin or insulated)
  • Bird / vermin guards, insect mesh
  • Louvred doors
  • Dampers
View all accessories
ADDITIONAL SECURITY OPTIONS
  • Blast Resistant Option: Can withstand up to 12.6psi blast pressure at an impulse of 77.8 psi-msec

ПРОЕКТИ

View All Louvre Projects

Specification

Guidance

The principal reason for using louvres is to allow the movement of air. But, louvre specification is a balance between form and function, with louvred façade appearance playing an important part in the selection process.

  • Performance Considerations
  • Design Considerations
  • Weather Louvre Testing
Learn more

Louvres

Какво има в брошурата
  • Водещи продукти в индустрията
  • Иновативни дизайнерски опции
  • Подробна техническа информация
  • Насоки за спецификацията на жалузите

0700 10 677
sales@assist.bg
Поръчайте мостра
Поискайте оценка
Поискайте техническа помощ

Меню

  • CS продукти
  • Проекти
  • Блог
  • За нас
  • Свържете се с нас
  • Изберете държава

Контакти

Местен дистрибутор на CS
АССИСТ
Бул. Европа 176, София 1331
0700 10 677
+359 2 824 1 824
+359 2 824 1 820
GPS 42.743503, 23.232862
Понеделник / Петък 9.00 - 18.00
sales@assist.bg

Политика за поверителност

Този уебсайт използва бисквитки, за да ни помогне да ви предоставим най-доброто изживяване, когато посещавате нашия уебсайт. Продължавайки да използвате този уебсайт, вие се съгласявате да използваме тези бисквитки. Научете повече за това как използваме бисквитките и как да ги управлявате по-долу в нашата политика за поверителност.
Политика за поверителност

Copyright © 2023 · Construction Specialties